Mới nhất

3WA1232-5LE02-4EA4-Z D85+F15+S55+T40
Hết hàng
$23,98696
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1232-5ME02-4EA4-Z D85+F15+S55+T40
Hết hàng
$25,00420
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1232-5CE02-4EA4-Z D85+F15+S55+T40
Hết hàng
$23,47264
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1232-5AE02-4EA4-Z D85+S55+T40
Hết hàng
$20,97648
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1232-5CE02-4EQ4-Z D85+F15+T40
Hết hàng
$22,92940
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5ME02-4EQ4-Z D85+F15+T40
Hết hàng
$24,46096
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5AE02-4EQ4-Z D85+T40
Hết hàng
$20,43324
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option T40 = Door sealing frame IP41
3WA1232-5LE02-4EQ4-Z D85+F15+S55+T40
Hết hàng
$24,41244
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1232-5ME02-4EQ4-Z D85+F15+S55+T40
Hết hàng
$25,42968
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1232-5CE02-4EQ4-Z D85+F15+S55+T40
Hết hàng
$23,89812
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1232-5AE02-4EQ4-Z D85+S55+T40
Hết hàng
$21,40196
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1232-5MF02-0AA0-Z D85+F15+T40
Hết hàng
$22,49496
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, without 1st Shunt trip option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5LF02-0AA0-Z D85+F15+T40
Hết hàng
$21,47768
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, without 1st Shunt trip option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5CF02-0AA0-Z D85+F15+T40
Hết hàng
$20,96336
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, without 1st Shunt trip option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5AF02-0AA0-Z D85+T40
Hết hàng
$18,46724
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, without 1st Shunt trip option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option T40 = Door sealing frame IP41
3WA1232-5CF02-0AA4-Z D85+F15+T40
Hết hàng
$21,32072
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5AF02-0AA4-Z D85+T40
Hết hàng
$18,82456
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option T40 = Door sealing frame IP41
3WA1232-5MF02-0AA4-Z D85+F15+T40
Hết hàng
$22,85228
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5LF02-0AA4-Z D85+F15+T40
Hết hàng
$21,83504
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5AF02-4EA4-Z D85+T40
Hết hàng
$20,92724
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option T40 = Door sealing frame IP41
3WA1232-5MF02-4EA4-Z D85+F15+T40
Hết hàng
$24,95496
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5LF02-4EA4-Z D85+F15+T40
Hết hàng
$23,93772
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5CF02-4EA4-Z D85+F15+T40
Hết hàng
$23,42340
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1232-5LF02-4EA4-Z D85+F15+S55+T40
Hết hàng
$24,90644
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=3200A up to 690V AC 50/60Hz, breaking capacity H Icu=100/85kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
Show another 24 product