Mới nhất

3WA1225-6ME02-0AA0-Z D85+F15+T40
Hết hàng
523.753.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, without 1st Shunt trip option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6CE02-0AA0-Z D85+F15+T40
Hết hàng
485.464.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, without 1st Shunt trip option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6LE02-0AA0-Z D85+F15+T40
Hết hàng
498.322.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, without 1st Shunt trip option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6ME02-0AA4-Z D85+F15+T40
Hết hàng
532.687.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6AE02-0AA4-Z D85+T40
Hết hàng
431.993.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option T40 = Door sealing frame IP41
3WA1225-6LE02-0AA4-Z D85+F15+T40
Hết hàng
507.255.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6CE02-0AA4-Z D85+F15+T40
Hết hàng
494.397.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6CE02-4EA4-Z D85+F15+T40
Hết hàng
546.965.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6LE02-4EA4-Z D85+F15+T40
Hết hàng
559.822.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6AE02-4EA4-Z D85+T40
Hết hàng
484.561.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option T40 = Door sealing frame IP41
3WA1225-6ME02-4EA4-Z D85+F15+T40
Hết hàng
585.254.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6LE02-4EQ4-Z D85+F15+T40
Hết hàng
570.460.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6ME02-4EA4-Z D85+F15+S55+T40
Hết hàng
609.472.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1225-6LE02-4EA4-Z D85+F15+S55+T40
Hết hàng
584.041.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1225-6CE02-4EA4-Z D85+F15+S55+T40
Hết hàng
571.183.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1225-6AE02-4EA4-Z D85+S55+T40
Hết hàng
508.779.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), without 2nd shunt trip, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1225-6CE02-4EQ4-Z D85+F15+T40
Hết hàng
557.602.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6AE02-4EQ4-Z D85+T40
Hết hàng
495.198.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option T40 = Door sealing frame IP41
3WA1225-6ME02-4EQ4-Z D85+F15+T40
Hết hàng
595.891.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option T40 = Door sealing frame IP41
3WA1225-6LE02-4EQ4-Z D85+F15+S55+T40
Hết hàng
594.678.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-1 Energy Efficiency, Voltage, Active energy Ea with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1225-6CE02-4EQ4-Z D85+F15+S55+T40
Hết hàng
581.820.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, able to communication, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1225-6AE02-4EQ4-Z D85+S55+T40
Hết hàng
519.416.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1225-6ME02-4EQ4-Z D85+F15+S55+T40
Hết hàng
620.109.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSI upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, with internal voltage tap on upper stab of circuit breaker, with voltage tap module VTM680 and power supply of ETU600, able to communication, integrated metering type PMF-2 Basic Power Monitoring, Voltage, Energy, Power, Power factor, Frequency, Unbalance, Temperature, with manual and motorized operating mechanism (M) 208-240 V AC / 220-250 V DC, Storage status and ready-to- close signaling switches, Auxiliary switches 2NO+2NC, Closing coil (CC) 100% OP 208-240 V AC / 220-250 V DC, applicable for continuous duty, without Remote trip alarm reset coil (RR), Undervoltage release (UVR) instantaneous (0,08 s) and short-delay (0,2 s), 208-240 V AC / 220-250 V DC, Shunt trip (ST) 100% OP 208-240 V AC / 220-250 V DC, suitable for continuous duty, option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option F15 = COM150 COM module Modbus RTU breaker internal Option S55 = Mutual mechanical interlocking with 2 m bowden cable for circuit breakers in fixed- mounted design necessary once for each circuit breaker. Option T40 = Door sealing frame IP41
3WA1225-6AF02-0AA0-Z D85+T40
Hết hàng
446.048.000 đ
Fixed-mounted circuit breaker IEC 60947-2, frame size 2, 3-poles, In=2500A up to 690V AC 50/60Hz, breaking capacity C Icu=130/100kA at 500/690V, Trip unit ETU600 LSIG upgrade ready , colordisplay, bluetooth and USB interface, Protection LT, ST, INST, GFx, N-protection required an external N-sensor, incl. trip alarm switch (1xCO), rear connection horizontal, without Com & metering function Manual operating mechanism with mechanical closing, without Spring charging motor, Ready-to-close signal. switch, Auxiliary switches 2NO+2NC, without Closing coil (CC), manual operating mechanism with mechanical closing, without Remote trip alarm reset coil (RR), without 2nd shunt trip, without 1st Shunt trip option D85 = ETU600 without backup battery type TADIRAN SL-350 size 1/2 AA required for internal clock. No restrictions on the protection functions. Option T40 = Door sealing frame IP41