Transmitters SITRANS LH100 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA housing material 316L (1.4404) measuring cell ceramics (96%) with fixed mounted LD-PE cable Measuring range: 0 - 3 mH2O Cable lenght: 10 m . . Sealing material between sensor and housing: FPM (standard) with ATEX II1 G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga
Transmitters SITRANS LH100 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA housing material 316L (1.4404) measuring cell ceramics (96%) with fixed mounted LD-PE cable Measuring range: 0 - 3 mH2O Cable lenght: 10 m . . Sealing material between sensor and housing: EPDM (for drinking water) with ATEX II1 G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga
Transmitters SITRANS LH100 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA housing material 316L (1.4404) measuring cell ceramics (96%) with fixed mounted LD-PE cable Measuring range: 0 - 4 mH2O Cable lenght: 10 m . . Sealing material between sensor and housing: FPM (standard) with ATEX II1 G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga
Transmitters SITRANS LH100 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA housing material 316L (1.4404) measuring cell ceramics (96%) with fixed mounted LD-PE cable Measuring range: 0 - 4 mH2O Cable lenght: 10 m . . Sealing material between sensor and housing: EPDM (for drinking water) with ATEX II1 G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga
Transmitters SITRANS LH100 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA housing material 316L (1.4404) measuring cell ceramics (96%) with fixed mounted LD-PE cable Measuring range: 0 - 5 mH2O Cable lenght: 10 m . . Sealing material between sensor and housing: FPM (standard) with ATEX II1 G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga
Transmitters SITRANS LH100 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA housing material 316L (1.4404) measuring cell ceramics (96%) with fixed mounted LD-PE cable Measuring range: 0 - 5 mH2O Cable lenght: 10 m . . Sealing material between sensor and housing: EPDM (for drinking water) with ATEX II1 G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga
Transmitters SITRANS LH100 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA housing material 316L (1.4404) measuring cell ceramics (96%) with fixed mounted LD-PE cable Measuring range: 0 - 6 mH2O Cable lenght: 10 m . . Sealing material between sensor and housing: FPM (standard) with ATEX II1 G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga
Transmitters SITRANS LH100 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA housing material 316L (1.4404) measuring cell ceramics (96%) with fixed mounted LD-PE cable Measuring range: 0 - 6 mH2O Cable lenght: 10 m . . Sealing material between sensor and housing: EPDM (for drinking water) with ATEX II1 G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga
Transmitters SITRANS LH100 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA housing material 316L (1.4404) measuring cell ceramics (96%) with fixed mounted LD-PE cable Measuring range: 0 - 10 mH2O Cable lenght: 20 m . . Sealing material between sensor and housing: FPM (standard) with ATEX II1 G Ex ia IIC T4 Ga and IECEx Ex ia IIC T4 Ga
Protection cap for SITRANS LH100
Transmitters SITRANS LH300 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA, measuring cell Al2O3 ceramics (99,6% purity) with fixed mounted cable material Measuring range: 0...1 mH2O Cable length: 5m Stainless steel 316L (1.4404) Protective cap PPE FKM (standard) without
Transmitters SITRANS LH300 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA, measuring cell Al2O3 ceramics (99,6% purity) with fixed mounted cable material Measuring range: 0...2 mH2O Cable length: 5m Stainless steel 316L (1.4404) Protective cap PPE FKM (standard) without
Transmitters SITRANS LH300 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA, measuring cell Al2O3 ceramics (99,6% purity) with fixed mounted cable material Measuring range: 0...3 mH2O Cable length: 10m Stainless steel 316L (1.4404) Protective cap PPE FKM (standard) without
Transmitters SITRANS LH300 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA, measuring cell Al2O3 ceramics (99,6% purity) with fixed mounted cable material Measuring range: 0...4 mH2O Cable length: 10m Stainless steel 316L (1.4404) Protective cap PPE FKM (standard) without
Transmitters SITRANS LH300 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA, measuring cell Al2O3 ceramics (99,6% purity) with fixed mounted cable material Measuring range: 0...5 mH2O Cable length: 10m Stainless steel 316L (1.4404) Protective cap PPE FKM (standard) without
Transmitters SITRANS LH300 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA, measuring cell Al2O3 ceramics (99,6% purity) with fixed mounted cable material Measuring range: 0...6 mH2O Cable length: 10m Stainless steel 316L (1.4404) Protective cap PPE FKM (standard) without
Transmitters SITRANS LH300 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA, measuring cell Al2O3 ceramics (99,6% purity) with fixed mounted cable material Measuring range: 0...10 mH2O Cable length: 20m Stainless steel 316L (1.4404) Protective cap PPE FKM (standard) without
Transmitters SITRANS LH300 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA, measuring cell Al2O3 ceramics (99,6% purity) with fixed mounted cable material Measuring range: 0...20 mH2O Cable length: 30m Stainless steel 316L (1.4404) Protective cap PPE FKM (standard) without
Transmitters SITRANS LH300 for hydrostatic level measurement, submersible transmitter, two-wire connection, 4...20 mA, measuring cell Al2O3 ceramics (99,6% purity) with fixed mounted cable material Measuring range: 0...40 mH2O Cable length: 50m Stainless steel 316L (1.4404) Protective cap PPE FKM (standard) without
Testing adapter for transmitter 7MF1575* connection G1/4" female, acc. EN837-1
Protective caps, ETFE as spare parts (10-pack)
7MF1565-3BG00-1AA1
0.0
Hết hàng
99.999.999 đ
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 6 bar, Overload- pressure 15 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
7MF1565-3BG00-1CA1
0.0
Hết hàng
99.999.999 đ
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 6 bar, Overload- pressure 15 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/4" male thread to EN837-1 (1/4"-BSP male) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version
7MF1565-3CA00-1AA1
0.0
Hết hàng
99.999.999 đ
SITRANS P200 Transmitters for pressure and absolute pressure for general applications Non-linearity: 0,25 percent (typically) wetted parts material:ceramics, stainless steel plus sealing material; non-wetted parts material: stainless steel Measuring range for gauge: 0 to 10 bar, Overload- pressure 25 bar Output signal: 4 to 20 mA two-wire connection, power supply DC 7 to 33 V without explosion protection Electrical connection: plug to DIN EN 175301-803-A, threat for packed gland M16 (with connector) Process connection: G1/2" male to EN 837-1 (1/2" BSP male) (standard for metric pressure ranges mbar, bar) Sealing material between sensor and housing: Viton (FPM, Standard) Standard version